Инструкция для Clavia NORD Lead 2X :: Страница 107 из 119
Service-Instruction.ru
инструкции pdf и руководства пользователя читать онлайн

Инструкция для Clavia NORD Lead 2X

Инструкция в формате - PDF
Количество страниц - 119 страниц
Размер - 3.3 МБ
Доступно - Бесплатное скачивание
Доступно - Онлайн чтение
background image

NORD LEAD 2X V1.0x

13. MIDI implementation: System Exclusive implementation

Page 105

S

S

S

S

Y

Y

Y

YS

S

S

ST

T

T

TE

E

E

EM

M

M

M

 E

 E

 E

 E

X

X

X

XC

C

C

CL

L

L

LU

U

U

US

S

S

SIIIIV

V

V

VE

E

E

E

    

IIIIM

M

M

MP

P

P

PL

L

L

LE

E

E

EM

M

M

ME

E

E

EN

N

N

NT

T

T

TA

A

A

AT

T

T

TIIIIO

O

O

ON

N

N

N

Numbers are in decimal except when preceded by a “$” character, in which case they are in hexadecimal 
format.

G

G

G

G

E

E

E

EN

N

N

NE

E

E

ER

R

R

RA

A

A

AL

L

L

L

 M

 M

 M

 M

E

E

E

ES

S

S

SS

S

S

SA

A

A

AG

G

G

GE

E

E

E

    

F

F

F

FO

O

O

OR

R

R

RM

M

M

MA

A

A

AT

T

T

T

P

P

P

P

A

A

A

AT

T

T

TC

C

C

CH

H

H

H

 D

 D

 D

 D

U

U

U

UM

M

M

MP

P

P

PS

S

S

S

This message contains the actual Patch Dump. One complete message contains the data for one Patch. 
It is transmitted 

from

 the Nord Lead 2X in one of two cases:

• When a Patch Dump is initiated from the front panel.

• When a valid Patch Dump Request message has been received.

This message should be sent 

to

 the Nord Lead 2X when you want to replace a Patch currently in the in-

strument, with a new one. 

The Message Type and Message Specification bytes in the Sys Ex message contains information about 
from which location the Patch Dump was sent. When a Patch is sent to the Nord Lead 2X, it will end 
up in this location.

• If the Sys Ex data 

for a complete Bank

 is sent (using the “Dump All” command), the Program location 

within the Bank is stored for each Patch. When any or all of these Patches are sent back to a Nord 
Lead 2X, they will be stored at their original Program Location, but in the Bank that is currently 
selected on the Nord Lead 2X.

• If the Sys Ex data for a single Patch is sent 

using the “Dump One” command

, it is considered being sent 

from the 

Edit Buffer of the selected Slot

. This means, that when the Patch is sent back to a Nord Lead 

2X, it will not actually be stored, but temporarily placed in the Edit Buffer of its original Slot.

Byte

Description

$F0

System Exclusive

$33

Manufacturer ID (clavia)

<Device ID>

= Global MIDI Channel, 0-15

$04

Model ID for Nord Lead 2X

<Message Type>

See each type of message, below.

<Message Specification>

See each type of message, below.

<Data 1>

This and following bytes depend on the Message Type and Message 
Specification. Some messages have no data bytes at all.

<Data 2>

<Data 3>

<etc.>

$F7

End Of Exclusive

Оглавление инструкции

Инструкции для синтезаторы Clavia

Популярные инструкции Clavia