PERIODIC MAINTENANCE 2-25
Periodic Maintenance Procedures
•
Position the crankshaft at 1,4 piston TDC.
TDC Mark [A] for #1, 4 Pistons
Timing Mark (Crankcase halves mating surface) [B]
•
Using the thickness gauge [A], measure the valve clear-
ance between the cam and the valve lifter.
Valve Clearance
Standard:
Exhaust
0.22
∼
0.31 mm (0.0087
∼
0.0122 in.)
Inlet
0.15
∼
0.24 mm (0.0059
∼
0.0094 in.)
○
When positioning #4 piston TDC at the end of the
compression stroke:
Inlet Valve Clearance of #2 and #4 Cylinders
Exhaust Valve Clearance of #3 and #4 Cylinders
Measuring Valve [A]
○
When positioning #1 piston TDC at the end of the
compression stroke:
Inlet Valve Clearance of #1 and #3 Cylinders
Exhaust Valve Clearance of #1 and #2 Cylinders
Measuring Valve [A]
If the valve clearance is not within the specified range,
first record the clearance, and then adjust it.
Valve Clearance Adjustment
•
To change the valve clearance, remove the camshaft
chain tensioner, camshafts and valve lifters. Replace the
shim with one of a different thickness.