16-74 ELECTRICAL SYSTEM
Immobilizer System (Equipped Models)
•
Connect the key registration unit [A].
Special Tool - Key Registration Unit: 57001-1582
•
Insert the master key to the ignition switch and turn it ON.
Verified
○
The FI indicator light [A] blinks to display the registration
mode (go to the next step).
Not Verified
○
The FI indicator light [A] blinks to display the collation error
(refer to the following failure illustrations).
Immobilizer Amplifier Failure
Master Key Collation Error
•
Turn the master key OFF and remove the master key.
○
The FI indicator light [A] blinks continuously to display that
the ECU is in the registration mode for 15 seconds.
NOTE
○
Insert next key and turn ON within 15 seconds after pre-
vious key is turned off and removed otherwise registra-
tion mode will be ended and the FI indicator light stops
flashing.
○
To return to the registration mode start the master key
verification procedure. This applies to all user key reg-
istration.