CRANKSHAFT/TRANSMISSION 9-19

Crankshaft and Connecting Rods

Crankshaft Side Clearance

•

Insert a thickness gauge [A] between the crankcase main
bearing and the crank web at the No. 2 journal [B] to
determine clearance.
If the clearance exceeds the service limit, replace the
crankcase halves as a set.

NOTE

○

The upper and lower crankcase halves are machined
at the factory in the assembled state, so the crankcase
halves must be replaced as a set.

Crankshaft Side Clearance

Standard:

0.05

∼

0.20 mm (0.0020

∼

0.0079 in.)

Service Limit: 0.40 mm (0.0157 in.)

Crankshaft Runout

•

Measure the crankshaft runout.
If the measurement exceeds the service limit, replace the
crankshaft.

Crankshaft Runout

Standard:

TIR 0.02 mm (0.0008 in.) or less

Service Limit: TIR 0.05 mm (0.0020 in.)

Crankshaft Main Bearing Insert/Journal Wear

•

Using a plastigage (press gauge) [A], measure the bear-
ing insert/journal [B] clearance.

NOTE

○

Tighten the crankcase bolts to the specified torque (see
Crankcase Assembly).

○

Do not turn the crankshaft during clearance measure-
ment.

○

Journal clearance less than 0.025 mm (0.00098 in.) can
not be measured by plastigage, however, using genuine
parts maintains the minimum standard clearance.

Crankshaft Main Bearing Insert/Journal Clearance

Standard:

0.020

∼

0.044 mm (0.0008

∼

0.0017 in.)

Service Limit: 0.07 mm (0.0028 in.)

If the clearance is within the standard, no bearing replace-
ment is required.
If the clearance is between 0.045 mm (0.0018 in.) and the
service limit (0.07 mm, 0.0028 in.), replace the bearing in-
serts [A] with inserts painted blue [B]. Check insert/journal
clearance with the plastigage. The clearance may exceed
the standard slightly, but it must not be less than the min-
imum in order to avoid bearing seizure.
If the clearance exceeds the service limit, measure the
diameter of the crankshaft main journal.