16-68 ELECTRICAL SYSTEM
Meter, Gauge, Indicator Unit
Speed Sensor Electric Source Check
•
Connect the 12 V battery and terminals in the same man-
ner as specified in the “Liquid Crystal Display (LCD) Seg-
ments Check”.
•
Set the hand tester to the DC 25 V range and connect it
to the terminals [12] and [9].
If the voltage is less than 8 V, replace the meter assembly.
Odometer Check
•
Check the odometer with the speedometer in the same
way.
If value indicated in the odometer is not added, replace
the meter assembly.
NOTE
○
The data is maintained even if the battery is discon-
nected.
○
When the figures come to 999999, they are stopped and
locked.
Trip A B Meter Check
•
Check the trip A B meters with the speedometer in the
same way.
If value indicated in the trip A B meters are not added,
replace the meter assembly.
•
Check that when the RESET button is pushed for more
than two seconds, the figure display turns to 0.0.
If the figure display does not indicate 0.0, replace the me-
ter assembly.
Water Temperature Warning Indicator Light (LED) Meter
Check
•
Connect the 12 V battery and terminals in the same man-
ner as specified in the “Liquid Crystal Display (LCD) Seg-
ments Check”.
•
Connect the variable rheostat [A] to the terminal [8] as
shown.
•
Check that the on or flash of warning indicator light [B]
matches the resistance value of the variable rheostat.
Resistance Value (
Ω
)
Warning Indicate
21.2
∼
28.2
ON
15.2
∼
21.2
Flash
•
If any display function does not work, replace the meter
assembly.