ELECTRICAL SYSTEM 16-97
Junction Box
The junction box [A] has fuses [B], relays, and diodes.
The relays and diodes can not be removed.
Junction Box Fuse Circuit Inspection
•
Remove the seats (see Frame chapter).
•
Remove the junction box [A].
•
Pull off the connectors [A] from the junction box [B].
•
Make sure all connector terminals are clean and tight, and
none of them have been bent.
Clean the dirty terminals, and straighten slightly-bent ter-
minals.
•
Check conductivity of the numbered terminals with the
hand tester.
○
Refer to the Junction Box Internal Circuit.
If the tester does not read as specified, replace the junc-
tion box.
Special Tool - Hand Tester: 57001-1394
Fuse Circuit Inspection
Tester
Connection
Tester
Reading (
Ω
)
Tester
Connection
Tester
Reading (
Ω
)
1-1A
0
1A-8
∞
1-2
0
2-8
∞
3A-4
0
3A-8
∞
6-5
0
6-2
∞
6-10
0
6-3A
∞
6-7
0
17-3A
∞
6-17
0