ELECTRICAL SYSTEM 16-77
Immobilizer System (Equipped Models)
•
The user key 2 is registered in the ECU.
○
The FI indicator light [A] blinks 3 times and stops for 1
second and then repeats this cycle.
○
This procedure has registered the master key and 2 user
keys.
•
Continue with the procedure to register an additional 3
user keys.
NOTE
○
The ECU can store up the six key codes (master key ×
1 and user key × 5).
User Key Indicator Flashes
FI Indicator
Light Blinks
FI Indicator
Light Stop
Remarks
User Key 3
4 times
1 seconds
Repeat
User Key 4
5 times
1 seconds
Repeat
User Key 5
6 times
1 seconds
Repeat
•
Turn OFF the ignition switch and wait for period of more
than 15 seconds.
•
The registration mode automatically ends.
•
FI indicator light goes off [A].
•
Remove the key registration unit and connect the immo-
bilizer Kawasaki self-diagnostic system connector.
NOTE
○
Turn the ignition switch ON with the registered user key.
○
Check that the engine can be started using all regis-