COOLING SYSTEM 4-17
Radiator Fan Switch, Water Temperature Sensor
CAUTION
The fan switch or the water temperature sensor
should never be allowed to fall on a hard surface.
Such a shock to their parts can damage them.
Radiator Fan Switch Removal
•
Drain the coolant (see Coolant Change in the Periodic
Maintenance chapter).
•
Remove:
Radiator Fan Switch Lead Connector [A]
Rubber Cap [B]
Radiator Fan Switch [C]
Radiator Fan Switch Installation
•
Tighten:
Torque - Radiator Fan Switch: 18 N·m (1.8 kgf·m, 13 ft·lb)
•
Fill the coolant (see Coolant Change in the Periodic Main-
tenance chapter).
Radiator Fan Switch Inspection
•
Refer to the Electrical System chapter for the Radiator
Fan Switch Inspection.
Water Temperature Sensor Removal/Installation
•
Refer to the Fuel System (DFI) chapter.
Water Temperature Sensor [A]
Water Temperature Sensor Inspection
•
Refer to the Electrical System chapter for the Water Tem-
perature Sensor Inspection.