CRANKSHAFT/TRANSMISSION 9-15
Crankshaft and Connecting Rods
•
Install new bolts in reused connecting rods.
•
Dent both bolt head and bolt tip with a punch as shown.
•
Before tightening, use a point micrometer [A] to measure
the length of new connecting rod bolts and record the val-
ues to find the bolt stretch.
Connecting Rod [B]
Mark here with a punch [C].
Nuts [D]
Fit micrometer pins into punch marks [E].
•
Apply a small amount of molybdenum disulfide oil to the
following:
Threads of Nuts and Bolts
Seating Surfaces of Nuts and Con-rods
•
Tighten the big end nuts until the bolt elongation reaches
the length specified in the table.
•
Check the length [F] of the connecting rod bolts.
If the stretch is more than the usable range, the bolt has
stretched too much. An overelongated bolt may break in
use.
Bolt Length
after tightening
–
Bolt Length
before tightening
=
Bolt Stretch
Connect-
ing Rod
Assy
Bolt
Nut
Usable Range of
Connecting Rod
Bolt Stretch
Attached to
new con-rod
New
Use the bolts
attached to
new con-rod.
New
0.24
∼
0.36 mm
(0.0094
∼
0.0142 in.)
Used
Used
Replace the
bolts with new
ones.
New
0.20
∼
0.32 mm
(0.0079
∼
0.0126 in.)
(2) Rotation Angle Method
If you don’t have a point micrometer, you may tighten the
nuts using the “Rotation Angle Method”.
•
Be sure to clean the bolts and nuts thoroughly with a high
-flash point solvent, because the new bolts and nuts are
treated with an anti-rust solution.
WARNING
Clean the bolts and nuts in a well-ventilated area,
and take care that there is no spark or flame any-
where near the working area. This includes any ap-
pliance with a pilot light. Because of the danger
or highly flammable liquids, do not use gasoline or
low-flash point solvents to clean them.
CAUTION
Immediately dry the bolts and nuts with com-
pressed air after cleaning.
Clean and dry the bolts and nuts completely.