3-50 FUEL SYSTEM (DFI)

Inlet Air Pressure Sensor (Service Code 12)

If the wiring is good, check the sensor for various vacuum.
If the output voltage for various vacuum is normal check
the ECU for its ground, and power supply (see ECU sec-
tion).

•

Remove the inlet air pressure sensor [A] and disconnect
the vacuum hose from the sensor.

○

Do not disconnect the sensor connector.

•

Connect an auxiliary hose [B] to the inlet air pressure sen-
sor.

•

Temporarily install the inlet air pressure sensor.

○

Connect a commercially available digital meter [C], vac-
uum gauge [D], the fork oil level gauge [E] and the har-
ness adapter to the inlet air pressure sensor.

Special Tools - Fork Oil Level Gauge: 57001-1290

Sensor Harness Adapter: 57001-1561

Inlet Air Pressure Sensor Output Voltage

Connection to Adapter

Meter (+)

→

BL (sensor Y/BL) lead

Meter (–)

→

Y/W (sensor BR/BK) lead

○

Turn the ignition switch ON.

○

Measure the inlet air pressure sensor output voltage from various vacuum readings, while pulling
the handle of the fork oil level gauge.

○

Check the inlet air pressure sensor output voltage, using the following formula and chart.

Suppose:

Pg: Vacuum Pressure (gauge) to Sensor

Pl: Local Atmospheric Pressure (absolute) measured by a barometer

Pv: Vacuum Pressure (absolute) to Sensor
Vv: Sensor Output Voltage (v)

then

Pv = Pl – Pg

For example, suppose the following data is obtained:

Pg = 8 cmHg (Vacuum gauge reading)

Pl = 70 cmHg (Varometer reading)

Vv = 3.2 V (Digital volt meter reading)

then

Pv = 70 – 8 = 62 cmHg (Abs)

Plot this Pv (62 cmHg) at a point [1] on the chart and draw a vertical line through the point. Then, you
can get the usable range [2] of the sensor output voltage.

Usable range = 3.04

∼

3.49 V

Plot Vv (3.2 V) on the vertical line.

→

Point [3].

Results: In the chart, Vv is within the usable range and the sensor is normal.