2-20 PERIODIC MAINTENANCE
Periodic Maintenance Procedures
•
Connect:
Fuel Pump Lead Connector [A]
Extension Tube [B]
Special Tool - Extension Tube: 57001-1578
•
Start the engine and warm it up thoroughly.
•
Check the idle speed.
Tachometer [A]
•
Open and close the throttle.
If the idle speed is out of the specified range, adjust it.
CAUTION
Do not measure the idle speed by the tachometer of
the meter unit.
•
While idling the engine, inspect the engine vacuum, using
the vacuum gauge [B].
Engine Vacuum
Standard:
29.7 ±1.333 kPa (225 ±10 mmHg) at Idle
Speed 1 100 ±50 r/min (rpm)
If any vacuum is not within the specifications, first syn-
chronize the balance of the left (#1, #2) and right (#3, #4)
assemblies.
Example:
#1: 165 mmHg
#2: 190 mmHg
#3: 170 mmHg
#4: 200 mmHg
•
With the engine at the correct idle speed, equalize the
lower vacuum of #3 and #4 (example 170 mmHg) to the
lower vacuum of #1 and #2 (example 165 mmHg) by turn-
ing the center adjusting screw [A].
NOTE
○
After adjustment, the final vacuum measurement be-
tween the lowest throttle valves may not be 165 mmHg
(in this example). The goal is to have the lower two vac-
uums between the left (#1 and #2) and right (#3 and #4)
banks be the same.
•
Open and close the throttle after each measurement and
adjust the idle speed as necessary.
•
Once the throttle valves have been synchronized, inspect
the main throttle sensor’s output voltage to ensure proper
operation (procedure is at the end of this section).