16-60 ELECTRICAL SYSTEM
Radiator Fan System
•
Slide out the dust cover [A].
•
Remove the fan switch [B].
•
Suspend the switch [A] in a container of coolant so that
the temperature-sensing projection and threaded portion
are submerged.
•
Suspend an accurate thermometer [B] in the coolant so
that the sensitive portions are located in almost the same
depth.
NOTE
○
The switch and thermometer must not touch the con-
tainer sides or bottom.
•
Place the container over a source of heat and gradu-
ally raise the temperature of the coolant while stirring the
coolant gently.
•
Using the hand tester, measure the internal resistance
of the switch across the terminals at the temperatures
shown in the table.
Special Tool - Hand Tester: 57001-1394
If the hand tester does not show the specified values, re-
place the switch.
Fan Switch Resistance
Rising temperature:
From OFF to ON at 93
∼
103°C (199
∼
217°F)
Falling temperature:
Fan stops with the temperature 3
∼
8°C (38
∼
46°F)
lower than the operation temperature range.
ON: Less than 0.5
Ω
OFF: More than 10 M
Ω
Water Temperature Sensor Inspection
•
Remove:
Fuel Tank (see Fuel chapter)
Meter Ground Bolt [A]
•
Disconnect the water temperature sensor connector [B].
•
Remove the water temperature sensor [C] (see Fuel Sys-
tem (DFI) chapter).