ELECTRICAL SYSTEM 16-85
Immobilizer System (Equipped Models)
User Key Collation Error
•
The user key 1 is registered in the ECU.
○
The FI indicator light [A] blinks 2 times and stops for 1
second and then repeats this cycle to indicate successful
registration of user key.
•
Turn off and remove the user key 1.
○
The FI indicator light [A] blinks to display the registration
mode codes.
NOTE
○
Insert next key and turn ON within 15 seconds after pre-
vious key is turned off and removed otherwise registra-
tion mode will be ended and the FI indicator light goes
off.
○
To return to the registration mode start the master key
verification procedure. This applies to all user key reg-
istration.
•
Insert the user key 2 to the ignition switch and turn it ON.
○
If there is any problem in the registration, the FI indicator
light [A] blinks to display the collation error code.
Immobilizer Amplifier Failure