FUEL SYSTEM (DFI) 3-55

Inlet Air Temperature Sensor (Service Code 13)

Sensor Resistance Inspection

•

Remove the inlet air temperature sensor.

•

Suspend the sensor [A] in a container of machine oil so
that the heat-sensitive portion is submerged.

•

Suspend a thermometer [B] with the heat-sensitive por-
tion [C] located in almost the same depth with the sensor.

NOTE

○

The sensor and thermometer must not touch the con-
tainer side or bottom.

•

Place the container over a source of heat and gradually
raise the temperature of the oil while stirring the oil gently
for even temperature.

•

Using a digital meter, measure the internal resistance
of the sensor across the terminals at the temperatures
shown in the table.

Inlet Air Temperature Sensor Resistance

Standard:

1.6

∼

3.7 k

Ω

at 20°C (68°F)

0.24

∼

0.43 k

Ω

at 80°C (176°F)

If the measurement is out of the range, replace the sensor.
If the measurement is within the specified, replace the
ECU.

Inlet Air Temperature Sensor Circuit

Inlet Air Temperature Sensor Circuit (Immobilizer Equipped Models)

A. ECU
B. Joint Connector D

C. Inlet Air Temperature Sensor