16-50 ELECTRICAL SYSTEM
Electric Starter System
•
Align the line [A] marked on the yoke with the through bolt
hole [B].
Brush Inspection
•
Measure the length [A] of each brush.
If any is worn down to the service limit, replace the carbon
brush holder assembly [B] and the terminal bolt assembly
[C].
Starter Motor Brush Length
Standard:
12 mm (0.47 in.)
Service Limit: 8.5 mm (0.33 in.)
Commutator Cleaning and Inspection
•
Smooth the commutator surface [A] if necessary with fine
emery cloth [B], and clean out the grooves.
•
Measure the diameter [A] of the commutator [B].
If the commutator diameter is less than the service limit,
replace the starter motor with a new one .
Commutator Diameter
Standard:
28 mm (1.10 in.)
Service Limit:
27 mm (1.06 in.)
Armature Inspection
•
Using the × 1
Ω
hand tester range, measure the resis-
tance between any two commutator segments [A].
Special Tool - Hand Tester: 57001-1394
If there is a high resistance or no reading (
∞
) between any
two segments, a winding is open and the starter motor
must be replaced.
•
Using the highest hand tester range, measure the resis-
tance between the segments and the shaft [B].
If there is any reading at all, the armature has a short and
the starter motor must be replaced.