2-52 PERIODIC MAINTENANCE
Periodic Maintenance Procedures
•
Loosen the air bleeder bolt [A] on the thermostat housing.
Front [B]
•
Replenish the coolant into the radiator until the coolant
begins to flow out the air bleeder bolt hole (that is, all the
remaining air is forced out).
•
Tap the radiator hoses to force any air bubbles caught
inside.
•
Fill the radiator up to the filler neck [A] with coolant.
•
Install the radiator cap.
•
Tighten the air bleeder bolt [B].
Torque - Thermostat Air Bleeder Bolt: 7.8 N·m (0.80 kgf·m,
69 in·lb)
•
Fill the reserve tank up to the “F” (full) level line [A] with
coolant and install the cap (in the photo, the muffler has
been removed for clarity).
•
Install the fuel tank (see Fuel System chapter).
•
Start the engine and warm it up thoroughly until the radi-
ator fan turns on and then stop the engine.
•
Check the coolant level in the reserve tank several times
while the engine is cooling down, and replenish as nec-
essary.
If the coolant level is lower than the “L” level line [B], add
coolant to the “F” level line.
CAUTION
Do not add more coolant above the “F” level line.