16-36 ELECTRICAL SYSTEM
Charging System
Alternator Inspection
There are three types of alternator failures: short, open
(lead burned out), or loss in rotor magnetism. A short or
open in one of the stator coil lead will result in either a low
output, or no output at all. A loss in rotor magnetism, which
may be caused by dropping or hitting the alternator, by leav-
ing it near an electromagnetic field, or just by aging, will re-
sult in low output.
•
To check the alternator output voltage, do the following
procedures.
○
Remove the regulator/rectifier and disconnect the con-
nector [A].
○
Connect the hand tester to the connector as shown.
Special Tool - Hand Tester: 57001-1394
○
Start the engine.
○
Run it at 3000 rpm of the engine speed.
○
Note the voltage readings.
Alternator Output Voltage
Tester
Connections
Reading
Range
Tester (+) to
Tester (–) to
@3000 rpm
One black
Another black
250 V AC
lead
lead
70 ~ 95 V
If the output voltage shows the value in the table, the alter-
nator operates properly and the regulator/rectifier is dam-
aged. A much lower reading than the value in the table
indicates that the alternator is defective.
○
Repeat the test for the other black leads.
Hand Tester [A]