16-36 ELECTRICAL SYSTEM

Charging System

Alternator Inspection

There are three types of alternator failures: short, open

(lead burned out), or loss in rotor magnetism. A short or
open in one of the stator coil lead will result in either a low
output, or no output at all. A loss in rotor magnetism, which
may be caused by dropping or hitting the alternator, by leav-
ing it near an electromagnetic field, or just by aging, will re-
sult in low output.

•

To check the alternator output voltage, do the following
procedures.

○

Remove the regulator/rectifier and disconnect the con-
nector [A].

○

Connect the hand tester to the connector as shown.

Special Tool - Hand Tester: 57001-1394

○

Start the engine.

○

Run it at 3000 rpm of the engine speed.

○

Note the voltage readings.

Alternator Output Voltage

Tester

Connections

Reading

Range

Tester (+) to

Tester (–) to

@3000 rpm

One black

Another black

250 V AC

lead

lead

70 ~ 95 V

If the output voltage shows the value in the table, the alter-
nator operates properly and the regulator/rectifier is dam-
aged. A much lower reading than the value in the table
indicates that the alternator is defective.

○

Repeat the test for the other black leads.

Hand Tester [A]