16-38 ELECTRICAL SYSTEM
Charging System
Regulator/Rectifier Inspection
•
Remove the regulator/rectifier (see Regulator/Rectifier
Removal).
•
Set the hand tester to the × 1 k
Ω
range and make the
measurements shown in the table.
Special Tool - Hand Tester: 57001-1394
•
Connect the hand tester to the regulator rectifier.
If the tester readings are not as specified, replace the
regulator/rectifier.
CAUTION
Use only Kawasaki Hand Tester 57001-1394 for this
test. A tester other than the Kawasaki Hand Tester
may show different readings.
If a megger or a meter with a large capacity battery
is used, the regulator/rectifier will be damaged.
Regulator/Rectifier Resistance
(Unit: k
Ω
)
Tester (+) Lead Connection
Termi-
nal
W
BK1
BK2
BK3
BK/Y
W
—
500
∼
∞
500
∼
∞
500
∼
∞
500
∼
∞
BK1
2
∼
20
—
500
∼
∞
500
∼
∞
500
∼
∞
BK2
2
∼
20
500
∼
∞
—
500
∼
∞
500
∼
∞
BK3
2
∼
20
500
∼
∞
500
∼
∞
—
500
∼
∞
(–)*
BK/Y
2
∼
40
2
∼
20
2
∼
20
2
∼
20
—
(
−
)*: Tester (
−
) Lead Connection