Инструкция для Kawasaki VULCAN 2000 (2003) :: Страница 524 из 633
Service-Instruction.ru
инструкции pdf и руководства пользователя читать онлайн

Инструкция для Kawasaki VULCAN 2000 (2003)

Инструкция в формате - PDF
Количество страниц - 633 страницы
Размер - 13 МБ
Доступно - Бесплатное скачивание
Доступно - Онлайн чтение
background image

16-46 ELECTRICAL SYSTEM

Ignition System

•

Connect a commercially available peak voltage adapter
[A] to the hand tester [B].

Recommended Tool: Peak Voltage Adapter

Type:

KEK-54-9-B

Brand:

KOWA SEIKI

Special Tool - Hand Tester: 57001-1394

•

Insert the adapter probes into the connector [C] of the
crankshaft sensor [D] as shown.

Connections:

Adapter

Adapter

(R, +)

(BK, –)

Crankshaft Sensor:

Y

←→

BK

NOTE

○

Be sure the battery is fully charged.

Hand Tester Range:

DC 10 V

•

Turn the ignition switch and the engine stop switch ON.

•

Pushing the starter button, turn the engine 4 ~ 5 seconds
with the transmission in neutral to measure the crankshaft
sensor peak voltage.

•

Repeat the measurements 5 or more times for one crank-
shaft sensor.

Crankshaft Sensor Peak Voltage

Standard:

3.0 V or more

If the reading is less than the specified value, replace the
crankshaft sensor.
If the reading is normal, check the ECU (see Fuel System
chapter).
If the peak voltage adapter is not available, the coil can
be checked for a broken or badly shorted winding with the
hand tester (special tool).

NOTE

○

Using the peak voltage adapter is a more reliable way
to determine the condition of the crankshaft sensor than
crankshaft sensor internal resistance measurements.

•

Disconnect the crankshaft sensor lead connector.

•

Set the hand tester [A] to the × 100

Ω

range and wire it to

the crankshaft sensor lead connector [B].

Connections:

Tester Connections

Crankshaft Sensor:

Y

←→

BK

If there is more resistance than the specified value, the
coil has an open wire and must be replaced. Much less
than this resistance means the coil is shorted, and must
be replaced.

Crankshaft Sensor Resistance

Standard:

420 ~ 520

Ω

•

Using the highest resistance range of the tester, measure
the resistance between the crankshaft sensor leads and
chassis ground.
Any tester reading less than infinity (

∞

) indicates a short,

necessitating replacement of the crankshaft sensor assy.

Оглавление инструкции

Инструкции для мототехника Kawasaki

Популярные инструкции Kawasaki