ELECTRICAL SYSTEM 16-69
Meter, Gauge
•
Remove:
Screws [A]
Holder [B]
•
Remove the grommet [C] from the lower meter cover [D].
NOTE
○
The water temperature warning LED light, oil pressure
warning LED light and FI indicator LED light can not be
exchanged.
•
Turn out the socket [A] counterclockwise.
○
These sockets are for the high beam indicator light, turn
signal indicator light and neutral indicator light.
Meter Unit Assembly
•
Insert the bulb [A] so that the projections [B] align with the
grooves [C] in the panel, and turn in the socket clockwise.
•
Fit the grommet [A] in the lower meter cover.
•
Install:
Holder [B]
Screws [C]
•
Tighten the band [D] as shown.