COOLING SYSTEM 4-15
Radiator
Radiator Cap Inspection
•
Check the condition of the top and bottom valve seals of
the radiator cap.
If any one of them shows visible damage, replace the cap.
Bottom Valve Seal [A]
Top Valve Seal [B]
Valve Spring [C]
•
Install the cap [A] on a cooling system pressure tester [B].
NOTE
○
Wet the cap sealing surfaces with water or coolant to
prevent pressure leakage.
•
Watching the pressure gauge, pump the pressure tester
to build up the pressure until the relief valve opens: the
gauge needle flicks downward. Stop pumping and mea-
sure leak time at once. The relief valve must open within
the specified range in the table below and the gauge nee-
dle must remain within the same range at least 6 seconds.
Radiator Cap Relief Pressure
Standard:
93
∼
123 kPa (0.95
∼
1.25 kgf/cm²,
13.5
∼
17.8 psi) for 6 seconds
If the cap holds too much pressure or cannot hold the
specified pressure, replace it with a new one.
Radiator Filler Neck Inspection
•
Remove the radiator cap.
•
Check the radiator filler neck for signs of damage.
•
Check the condition of the top and bottom sealing seats
[A] in the filler neck. They must be smooth and clean for
the radiator cap to function properly.
Front [B]