FUEL SYSTEM (DFI) 3-91
Subthrottle Valve Actuator (Service Code 62)
Input Voltage Inspection
NOTE
○
Be sure the battery is fully charged.
•
Turn the ignition switch OFF.
•
Remove the fuel tank (see this chapter).
•
Connect the peak voltage adaper [A] and a digital meter
[B] to the connector [C], using the needle adapter set [D].
Recommended Tool - Peak Voltage Adapter
Type: KEK-54–9–B
Brand: KOWA SEIKI
Special Tool - Needle Adapter Set: 57001-1457
•
Temporarilly install the fuel tank.
○
Connect the following
Fuel Hose
Meter Leads Connector
Fuel Pump Leads Connector
Fuel Level Sensor Leads Connector
Subthrottle Valve Actuator Input Voltage
Connections to Harness Connector
(I)
Meter (+)
→
BK lead [1]
Meter (–)
→
P lead [2]
(II)
Meter (+)
→
G lead [3]
Meter (–)
→
W/BL lead [4]
•
Measure the actuator input voltage with the engine
stopped, and with the connector joined.
•
Turn the ignition switch ON.
Input Voltage at Sensor
Standard:
about 8.5
∼
10.5 V DC
If the reading is out of the range, check the wiring to ECU
(see wiring diagram in this section).
If the wiring is good, replace the ECU.
•
Install the fuel tank.
○
Be sure the fuel tank dampers are in position.