7-14 ENGINE LUBRICATION SYSTEM

Oil Pan

Blowby Gas System Inspection

•

Be certain that the hose is routed without being flattened
or kinked, and is connected correctly to the air cleaner
base.
If it is not, correct it.

•

Inspect the breather hose [A], breather pipe [B], and the
air cleaner drain cap for damage or signs of deterioration.

○

The hose and drain cap should not be hard and brittle,
nor should be soft or swollen.
Replace them if any cranks or swelling are noticed.

•

Check that the hose is securely connected.

Breather Drain Cleaning

•

Refer to Air Cleaner Housing Installation in the Fuel (DFI)
System chapter.