7-14 ENGINE LUBRICATION SYSTEM
Oil Pan
Blowby Gas System Inspection
•
Be certain that the hose is routed without being flattened
or kinked, and is connected correctly to the air cleaner
base.
If it is not, correct it.
•
Inspect the breather hose [A], breather pipe [B], and the
air cleaner drain cap for damage or signs of deterioration.
○
The hose and drain cap should not be hard and brittle,
nor should be soft or swollen.
Replace them if any cranks or swelling are noticed.
•
Check that the hose is securely connected.
Breather Drain Cleaning
•
Refer to Air Cleaner Housing Installation in the Fuel (DFI)
System chapter.