16-74 ELECTRICAL SYSTEM
Meter, Gauge
Speed Sensor Power Supply Voltage Inspection:
•
Connect the leads in the same circuit as for the LCD Seg-
ment Inspection, Check 2.
•
Set the hand tester [A] to DC25 V, check the voltage be-
tween terminal [10] and battery negative lead.
Connections
Hand Tester (+)
→
Terminal [10]
Hand Tester (–)
→
Battery Negative (–) Terminal
Special Tool - Hand Tester: 57001–1394
If the voltage is less than 6 V, replace the meter unit.
ODO Meter Inspection:
•
Connect the leads in the same circuit as for the
Speedometer Inspection.
•
Push the mode button to ODO [A].
•
Raise the input frequency of the oscillator to quickly see
the result of this inspection.
If the value indicated by the odo meter does not increase,
replace the meter unit.
TRIP Meter Inspection:
•
Connect the leads in the same circuit as for the
Speedometer Inspection.
•
Push the mode button to TRIP [A].
•
Rise the input frequency of the oscillator to quickly see
the result of this inspection.
If the value indicated by the trip meter does not increase,
replace the meter unit.
Fuel Level Gauge Inspection:
•
Connect the leads in the same circuit as for the LCD seg-
ment inspection, Check 2.
•
Connect a variable rheostat [A] to the terminal [12] and
battery negative lead as shown.
•
Check that the number of segments [B] matches the re-
sistance value of the variable rheostat.
○
When terminal [12] is connected, one segment should ap-
pear about 10 ~ 15 seconds.
Resistance (
Ω
)
Number of Segments
50
5
100
3
210
1
Resistance values are standard and they have tolerance.
If this indicator function does not work, replace the meter
unit.