16-32 ELECTRICAL SYSTEM
Battery
system. Therefore, replace a sealed battery only on a motorcycle which was originally equipped with
a sealed battery.
Be careful, if a sealed battery is installed on a motorcycle which had an ordinary battery as original
equipment, the sealed battery’s life will be shortened.
Charging Condition Inspection
○
Battery charging condition can be checked by measuring
battery terminal voltage with a digital voltmeter [A].
•
Remove:
Seats (see Frame chapter)
Battery Cover
•
Disconnect the battery terminals.
CAUTION
Be sure to disconnect the negative (–) cable first.
•
Measure the battery terminal voltage.
NOTE
○
Measure with a digital voltmeter which can be read one
decimal place voltage.
If the reading is 12.6 V or more, no refresh charge is re-
quired, however, if the read is below the specified, refresh
charge is required.
Battery Terminal Voltage
Standard:
12.6 V or more
Refreshing Charge
•
Remove the battery [A] (see Battery Removal).
•
Do refresh charge by following method according to the
battery terminal voltage.
WARNING
This battery is sealed type. Never remove sealing
cap [B] even at charging. Never add water. Charge
with current and time as stated below.