16-80 ELECTRICAL SYSTEM
Air Switching Valve
Air Switching Valve Operation Test
•
Pull the air switching valve hose [A] out of the right air
cleaner base.
•
Start the engine and run it at idle speed.
•
Plug the air switching valve hose end with your finger and
feel vacuum pulsing in the hose.
If there is no vacuum pulsation, check the hose line for
leak. If there is no leak, check the air switching valve (see
Air Switching Valve Unit Test).
•
Apply a soap and water solution or rubber lubricant to the
end of the air switching valve hose [A] and install the hose
on the fitting [B].
Air Switching Valve Unit Test
•
Remove the air switching valve (see Engine Top End
chapter).
•
Set the hand tester [A] to the ×
Ω
range and connect it to
the air switching valve terminals as shown.
Special Tool - Hand Tester: 57001-1394
Air Switching Valve Resistance
Standard: 18
∼
22
Ω
at 20°C (68°F)
If the resistance reading is except the specified value, re-
place it with a new one.
•
Connect the 12 V battery [A] to the air switching valve
terminals as shown.
•
Blow the air to the inlet air duct [A], and make sure does
not flow the blown air from the outlet air ducts [B].