GENERAL INFORMATION 1-13
Technical Information – Oxygen Sensor
The sensor, uses the fresh air as the oxygen reference,
and consists of a passageway to lead the fresh air inside
the tubular element. Installed in this passageway is, a air
permeable filter that allows the fresh air to pass through,
but won’t allow moisture through. This keeps the sensor in
touch with the atmosphere.
At a normal temperature, Zirconia (solid electrolyte) is
an insulator and not able to sense the gases. Since the
exhaust gas temperature does not become hot instantly,
it takes sometime before the sensor starts to work. To
solve the problem of the slow temperature increase of ex-
haust gases (which warms the electrolyte element), a built
-in heater located inside the tubular element increases the
temperature of the sensor so it can operate at a low ex-
haust gas temperature. Furthermore this built-in heater
helps keep the sensor at a constant temperature.
Air/Fuel Ratio Control By Oxygen Sensor
”
λ
=1” indicates the optimum air/fuel ratio point, meaning
the air/fuel ratio at which optimum (complete) combustion
can be obtained. In the proximity of this mixture, the purifi-
cation efficiency of the catalyst will be maximized.
The purification ratio of the three kinds of gas, HC (hy-
drocarbons), CO (carbon monoxide), Nox (nitrogen oxides)
using the ternary (three) catalyst is shown in Fig. 4.
The best purification rate is at the zone where the oxy-
gen sensor’s signal shows the sharp changes. This zone is
called the “window” and if the oxygen sensor signal moves
back and forth between the rich side (fuel rich) and lean
side (fuel lean) from the oprimum mix ratio (but still within
the width of the window), it indicates that the exhaust gas
is in a good purification rate zone.