ELECTRICAL SYSTEM 16-37
Charging System
•
Check the stator coil resistance as follows:
○
Turn off the ignition switch.
○
Connect the hand tester [A] to the connector as shown in
the table.
○
Note the resistance readings.
Stator Coil Resistance
Tester
Connections
Range
Tester (+) to
Tester (–) to
Reading
One black
Another black
×1
Ω
lead
lead
0.18 ~ 0.22
Ω
If there is more resistance than shown in the table, or no
hand tester reading (infinity), the stator has an open wire
and must be replaced. Much less than this resistance
means the stator is shorted, and must be replaced.
•
Using the highest resistance range of the hand tester,
measure the resistance between each of the black leads
and chassis ground.
Any hand tester reading less than infinity (
∞
) indicates a
short, necessitating stator replacement.
If the stator coil has normal resistance, but the voltage
check showed the alternator to be defective, then the rotor
magnets have probably weakened, and the rotor must be
replaced.
○
Repeat the test for the other black leads.
○
Repeat the test for the inside alternator connector.
Regulator/Rectifier Removal
•
Remove:
Regulator/Rectifier Mounting Bolts [A]
Regulator/Rectifier [B]
•
Disconnect the connectors [A] from the regulator/rectifier.
Regulator/Rectifier Installation
•
Run the regulator/rectifier leads according to the Cable,
Wire, and Hose Routing section in the Appendix chapter.
•
Tighten:
Torque - Regulator/Rectifier Bolts: 8.8 N·m (0.90 kgf·m, 78
in·lb)