3-58 FUEL SYSTEM (DFI)
Atmospheric Pressure Sensor (Service Code 15)
Output Voltage Inspection
•
Measure the output voltage at the ECU in the same way
as input voltage inspection. Note the following.
Digital Meter [A]
ECU Connector [B]
Atmospheric Pressure Sensor Output Voltage
Connections to ECU
Meter (+)
→
G/W lead (terminal 20)
Meter (–)
→
BR/BK lead (terminal 25)
Output Voltage
Usable Range:
3.80
∼
4.20 V DC at the standard
atmospheric pressure (101.32 kPa,
76 cmHg abs.)
NOTE
○
The output voltage changes according to the local at-
mospheric pressure.
○
The atmospheric sensor output voltage is based on
a nearly perfect vacuum in the small chamber of the
sensor. So, the sensor indicates absolute atmospheric
pressure.
If the output voltage is normal, check the output voltage
for atmospheric pressure other than 76 cmHg (abs) (see
Inlet Air Pressure Sensor section in this chapter). If the
output voltage changes within the usable range as atmo-
spheric pressure changes, the sensor is normal and the
ECU is suspect. Replace the ECU.
If the output voltage is out of the usable range, replace
the sensor.
1. ECU
2. Joint Connector
3. Atmospheric Pressure Sensor