ELECTRICAL SYSTEM 16-71
Meter, Gauge
Check 2 :
•
Using the auxiliary lead, connect the battery positive ter-
minal to terminal [8].
•
Verify that all the LCD segments (the letters and num-
bers of the liquid crystal display) to appear for 3 seconds,
and the speedometer needle momentary points to the last
reading and then return to the 0 position. Then the clock
or meters operates normally depending on the mode se-
lected.
•
Disconnect the terminal [8].
•
Verity that all the LCD segments and symbols disappear.
If the display function does not work, replace the meter
unit.
Mode Button Operation Checks:
•
Connect the lead in the same circuit as for the LCD Seg-
ment Inspection, Check 2.
•
Check that the display [A] changes to the CLOCK, ODO,
and TRIP display each time the mode button [B] is
pushed.
If the display does not work, replace the meter unit.
•
Push the mode button [A] to TRIP and push the reset
button [B] more than 2 seconds. The display shows “0.0”.
If the display does not show “0.0”, replace the meter unit.