3-16 COOLING SYSTEM

Radiator Fan Switch, Water Temperature Switch

CAUTION

The fan switch or the water temperature switch
should never be allowed to fall on a hard surface.
Such a shock to these parts can damage them.

Radiator Fan Switch Removal

•

Pull out the cover [A].

•

Disconnect the fan switch connector [B].

•

Remove the radiator fan switch [C].

Water Temperature Switch Removal

•

Drain the coolant.

•

Remove the fuel tank (see Fuel System chapter).

•

Disconnect the lead [A] and remove the water tempera-
ture switch [B].

Radiator Fan Switch, Water Temperature Switch

Installation

•

Apply silicone sealant to the threads before mounting the
water temperature switch.

Sealant - Kawasaki Bond (Silicone Sealant): 56019-120

○

Do not apply silicone sealant to the radiator fan switch on
the radiator.

•

Tighten the water temperature switch and the fan switch.

Torque - Water Temperature Switch: 7.8 N·m (0.80 kgf·m,

69 in·lb)

Radiator Fan Switch: 18 N·m (1.8 kgf·m, 13.0 ft·lb)

Radiator Fan Switch, Water Temperature Switch

Inspection

•

Refer to the Electrical System chapter for these inspec-
tions.