15-20 ELECTRICAL SYSTEM

Battery

•

Take the electrolyte container out of the vinyl bag.

•

Detach the seal caps [A] from the container.

NOTE

○

Do not discard the seal cap because it is used as the
battery plugs later.

○

Do not peel back or pierce the seals [B] on the container.

•

Place the electrolyte container upside down aligning the
six seals with the six battery filler ports.

•

Push the container down strongly enough to break the
seals. Now the electrolyte should start to flow into the
battery.

NOTE

○

Do not tilt the container as the electrolyte flow may be
interrupted.

•

Make sure air bubbles [A] are coming up from all six filler
ports.

○

Leave the container this way for 5 minutes or longer.

NOTE

○

If no air bubbles are coming up from a filler port, tap [B]
the bottom of the container two or three times. Never
remove the container from the battery.

CAUTION

Fill the electrolyte into the battery until the con-
tainer is completely emptied.

•

Be certain that all the electrolyte has flowed out.

•

Tap the bottom the same way as above if there is any
electrolyte left in the container.

•

Now pull the container gently out of the battery.

•

Let the battery sit for

20

minutes. During this time, the

electrolyte permeates the special separators and the gas
generated by chemical reaction is released.

•

Fit the seal caps [A] tightly into the filler ports until the seal
cap is at the same level as the top of the battery.

NOTE

○

Do not hammer. Press down evenly with both hands.

CAUTION

Once you installed the seal caps after filling the bat-
tery, never remove it, nor add any water or elec-
trolyte.