CRANKSHAFT/TRANSMISSION 8-15
Crankshaft/Connecting Rods
•
Select the proper bearing insert in accordance with the
combination of the connecting rod and crankshaft coding.
•
Install the new insert in the connecting rod and check in-
sert/journal clearance with a plastigage.
Connecting Rod Big End Bearing Insert Selection
Bearing Insert
Con-rod Bore
Diameter Mark
Crankpin
Diameter Mark
Size Color
Part Number
○
○
None
None
Black
92028-1349
○
None
Blue
92028-1348
None
○
Brown
92028-1350
Crankshaft Runout
•
Measure the crankshaft runout.
○
Set the crankshaft in a flywheel alignment jig or on V
blocks.
○
Set a dial gauge against the points indicated.
○
Turn the crankshaft slowly to measure the runout. The dif-
ference between the highest and lowest dial gauge read-
ings (TIR) is the amount of runout.
If the measurement exceeds the service limit, replace the
crankshaft.
Crankshaft Runout
Service Limit:
0.05 mm (0.0020 in.) TIR
Crankshaft Main Bearing Insert/Journal Clearance
•
Measure the bearing insert/journal clearance using a
plastigage.
○
Split the crankcase and wipe each bearing insert and jour-
nal surface clean of oil.
○
Cut strips of plastigage to bearing insert width, and place
a strip on each journal parallel to the crankshaft so that the
plastigage will be compressed between the journal and
the bearing insert.
○
Install the lower crankcase half, and tighten the case bolts
to the specified torque.
Torque - Crankcase 8 mm Bolts: 27 N·m (2.8 kgf·m, 20 ft·lb)
Crankcase 6 mm Bolts: 12 N·m (1.2 kgf·m, 8.5 ft·lb)
NOTE
○
Do not turn the crankshaft during clearance measure-
ment.
○
Remove the lower crankcase half and measure the plas-
tigage width [A] to determine the bearing insert/journal [B]
clearance.
Crankshaft Main Bearing Insert/Journal Clearance
Standard:
0.020
∼
0.044 mm (0.0008
∼
0.0017 in.)
Service Limit: 0.08 mm (0.0032 in.)