15-22 ELECTRICAL SYSTEM

Battery

Interchange

The sealed battery can fully display its performance only when combined with a proper vehicle elec-

tric system. Therefore, replace the sealed battery only on a motorcycle which was originally equipped
with the sealed battery.

Be careful, if a sealed battery is installed on a motorcycle which had an ordinary battery as original

equipment, the sealed battery’s life will be shortened.

Charging Condition Inspection

Battery charging condition can be checked by measuring

battery terminal voltage.

•

Remove the seat (see Frame chapter).

•

Disconnect the battery terminals.

CAUTION

Be sure to disconnect the negative terminal first.

•

Measure the battery terminal voltage.

NOTE

○

Measure with a digital voltmeter [A] which can be read
one decimal place voltage.

If the reading is below the specified, refreshing charge is
required.

Battery Terminal Voltage

Standard:

12.8 V or more

Refreshing Charge

•

Disconnect the battery terminals (see Charging Condition
Inspection).

•

Remove the battery [A].

•

Do refresh-charge by following method according to the
battery terminal voltage.

WARNING

This battery is sealed type. Never remove seal cap
[B] even at charging. Never add water. Charge with
current and time as stated below.

Terminal Voltage: 11.5

∼

less than 12.8 V

Standard Charge

1.2 A × 5

∼

10 h (see following chart)

Quick Charge

5.0 A × 1.0 h

CAUTION

If possible, do not quick charge. If the quick charge
is done due to unavoidable circumstances, do stan-
dard charge later on.

Terminal Voltage: less than 11.5 V

Charging Method 1.2 A × 20 h