Инструкция для Kawasaki ER5 (2004) :: Страница 68 из 334
Service-Instruction.ru
инструкции pdf и руководства пользователя читать онлайн
background image

3-6 COOLING SYSTEM

Coolant

Coolant Filling

•

Install the drain plug [A]. Always replace the gasket with
a new one, if it is damaged.

•

Tighten the drain plug.

Torque - Coolant Drain Plug: 11 N·m (1.1 kgf·m, 95 in·lb)

•

Fill [A] the radiator up to the bottom of the radiator filler
neck [B] with coolant [C], and install the cap turning it
clockwise about 1/4 turn.

NOTE

○

Pour in the coolant slowly so that it can expel the air
from the engine and radiator.

○

The radiator cap must be installed in two steps. First
turn the cap clockwise to the first stop. Then push down
on it and turn it the rest of the way.

CAUTION

Soft or distilled water must be used with the an-
tifreeze (see Specifications in this chapter) in the
cooling system.
If hard water is used in the system, it causes scales
accumulation in the water passages, and consider-
ably reduces the efficiency of the cooling system.

Water and Coolant Mixture Ratio (when shipping)

Soft Water

50%

Coolant

50%

Freezing Point

–35°C (–31°F)

Total Amount

1.7 L (1.8 US qt)

NOTE

○

Choose a suitable mixture ratio by referring to the
coolant manufacturer’s directions.

•

Remove the fuel tank (see Fuel System chapter).

•

Bleed the air from the cooling system while the engine is
running.

○

Start the engine with the radiator cap removed and run it
until no more air bubbles [A] can be seen in the coolant.

○

Tap the radiator hoses to force any air bubbles caught
inside.

○

Stop the engine and add coolant up to the radiator filler
neck.

•

Install the radiator cap.