ELECTRICAL SYSTEM 15-63
Switches and Sensors
Water Temperature Switch Inspection
•
Remove the water temperature switch (see Cooling Sys-
tem chapter).
•
Suspend the switch [A] in a container of coolant so that
the temperature sensing projection and threaded portion
are submerged.
•
Suspend an accurate thermometer [B] in the coolant so
that the sensitive portions [C] are located in almost the
same depth.
NOTE
○
The switch and thermometer must not touch the con-
tainer sides or bottom.
•
Place the container over a source of heat and gradu-
ally raise the temperature of the coolant while stirring the
coolant gently.
•
Using the hand tester, measure the internal resistance of
the switch across the terminal and the body at the tem-
peratures shown in the table.
If the hand tester does not show the specified values, re-
place the switch.
Water Temperature Switch Connections
Rising temperature:
From OFF to ON at 110
∼
120°C (230
∼
248°F)
Falling temperature:
From ON to OFF at 108°C (226°F)
∼
temperature less
than ON temperature
ON: Less than 0.5
Ω
OFF: More than 1 M
Ω
Fuel Gauge Operation Inspection
•
Remove the fuel tank, and disconnect the fuel level sen-
sor lead connector.
•
Turn the ignition switch ON.
•
Open or short the terminals in the fuel level sensor lead
connector from the main harness using an auxiliary lead.
Then check the operation of the fuel gauge [A].
If the gauge is not read (E) when opening and/or is not
read (F) when shorting, the trouble is with the gauge
and/or wiring.
•
Check the fuel gauge circuit wiring.
If all wiring and components other than the gauge are
good, the gauge is defective, and replace the fuel gauge.