Инструкция для Kawasaki ER5 (2004) :: Страница 281 из 334
Service-Instruction.ru
инструкции pdf и руководства пользователя читать онлайн
background image

ELECTRICAL SYSTEM 15-23

Battery

NOTE

○

If the current does not flow when charging, raise the
voltage initially (25 V as maximum), and let down the
voltage to charge when the current starts to flow as a
yardstick. If ammeter shows no change in current after
5 minutes, you need a new battery. The current, if it can
flow into the battery, tends to become excessive. Adjust
the voltage as often as possible to keep the current at
standard value (1.2 A).

Battery [A]
Battery Charger [B]
Standard Value [C]
Current starts to flow [D]

•

Determine battery condition after refreshing charge.

○

Determine the condition of the battery 30 minutes after
completion of the charge by measuring the terminal volt-
age according to the table below.

Criteria

Judgement

12.8 V or higher

Good

12.0

∼

less than 12.8 V

Charge insufficient

→

Recharge.

less than 12.0 V

Unserviceable

→

Replace

Оглавление инструкции

Инструкции для мототехника Kawasaki

Популярные инструкции Kawasaki