3-20 FUEL SYSTEM

Air Cleaner

Fuel Tank Bracket [A]
Air Cleaner Ducts
Breather Tube
Air Suction Valve Hose

•

Remove the air cleaner housing [A].

Air Cleaner Housing Installation

•

Air cleaner housing installation is the reverse of removal.

Air Cleaner Draining

A drain hose [A] is provided beneath the air cleaner hos-

ing, and catches the water or oil from the bottom of the hose.
Usually water or oil does not collect at the bottom of the
hose. In the event that rain water is drawn in through the
air cleaner, or if engine oil is blown back, drain the housing.

•

Check the drain hose.
If any water or oil accumulates in the hose, drain it by
pinching the lower end [B] of the drain hose.

•

Be sure to install the plug firmly, or the air will be drawn
in through it.

WARNING

Be sure to install the plug in the drain hose after
draining. Oil could drain from the open hose and
get on the tires which could cause an accident and
injury.