Инструкция для Kawasaki KLE500 (2004) :: Страница 335 из 401
Service-Instruction.ru
инструкции pdf и руководства пользователя читать онлайн
background image

ELECTRICAL SYSTEM 16-21

Battery

•

Gently remove the container from the battery.

•

Let the battery sit for

60

minutes prior to charging to allow

the electrolyte to permeate into the plates for optimum
performance.

NOTE

○

Charging the battery immediately after filling can
shorten service life. Let the battery sit for at least

60

minutes after filling.

Initial Charge

•

Place the strip [A] of caps loosely over the filler ports.

•

Newly activated sealed batteries require an initial charge.

Standard Charge

1.2 A × 5

∼

10 hours

If using a recommended battery charger, follow the
charger’s instructions for newly activated sealed battery.

Kawasaki-recommended chargers:

Optimate III
Yuasa 1.5 Amp Automatic Charger
Battery Mate 150-9

If the above chargers are not available, use equivalent
one.

NOTE

○

Charging rates will vary depending on how long the
battery has been stored, temperature, and the type of
charger used. Let battery sit 30 minutes after initial
charge, then check voltage using a voltmeter. If it is
not at least 12.8 volts, repeat charging cycle.

•

After charging is completed, press down firmly with both
hands to seat the strip of caps [A] into the battery (don’t
pound or hammer). When properly installed, the strip of
the caps will be level with the top of the battery.

CAUTION

Once the strip of the caps [A] is installed onto the
battery, never remove the caps, nor add water or
electrolyte to the battery.

NOTE

○

To ensure maximum battery life and customer satisfac-
tion, it is recommended the battery be load tested at
three times its amp-hour rating for 15 seconds.
Re-check voltage and if less than 12.8 volts repeat the
charging cycle and load test. If still below 12.8 volts, the
battery is defective.

Precautions

1) No need of topping-up

No topping-up is necessary in this battery until it ends its life under normal use. Forcibly prying off
the seal cap to add water is very dangerous. Never do that.

2) Refreshing charge

If an engine will not start, a horn sounds weak, or lights are dim, it indicates the battery has been
discharged. Give refresh charge for 5 to 10 hours with charge current shown in the specification
(see Refreshing Charge).

Оглавление инструкции

Инструкции для мототехника Kawasaki

Популярные инструкции Kawasaki