Инструкция по эксплуатации для Kawasaki KLE500 (2004) :: Страница 360 из 401
Service-Instruction.ru
инструкции pdf и руководства пользователя читать онлайн
background image

16-46 ELECTRICAL SYSTEM

Electric Starter System

•

Make sure that the marks [A] on the covers and yoke
housing align with each other.

•

Tighten the through bolts.

Torque - Starter Motor Through Bolts: 6.9 N·m (0.7 kgf·m,

65 in·lb)

Brush Inspection

•

Measure the length [A] of each brush.
If any is worn down to the service limit, replace the brush
plate assembly [B].

Starter Motor Brush Length

Standard:

12.0

∼

12.5 mm (0.47

∼

0.49 in.)

Service Limit:

8.5 mm (0.34 in.)

Brush Spring Inspection

•

Check that the brush springs are in place and will snap
the brushes firmly into place.
If not, reinstall or replace the spring.

Commutator Cleaning and Inspection

•

Smooth the commutator surface [A] if necessary with fine
emery cloth [B], and clean out the grooves.

•

Measure the diameter [A] of the commutator [B].
Replace the starter motor with a new one if the commu-
tator diameter is less than the service limit.

Commutator Diameter

Standard:

28 mm (1.10 in.)

Service Limit:

27 mm (1.06 in.)

Оглавление инструкции

Инструкции для мототехника Kawasaki

Популярные инструкции Kawasaki