4-18 COOLING SYSTEM

Radiator Fan Switch, Water Temperature Switch

CAUTION

The fan switch or the water temperature switch
should never be allowed to fall on a hard surface.
Such a shock to these parts can damage them.

Radiator Fan Switch Removal

•

Remove the Left Lower Fairing (see Lower Fairing Re-
moval in the Frame chapter).

•

Disconnect the fan switch connector [A] and remove the
radiator fan switch [B].

Water Temperature Switch Removal

•

Drain the coolant.

•

Remove the left lower fairing (see Lower Fairing Removal
in the Frame chapter).

•

Disconnect the lead [A] and remove the water tempera-
ture switch [B].

Radiator Fan Switch, Water Temperature Switch

Installation

•

Apply silicone sealant to the threads before mounting the
water temperature switch.

Sealant - Kawasaki Bond (Silicone Sealant): 56019-120

○

Do not apply silicone sealant to the radiator fan switch on
the radiator.

•

Tighten the water temperature switch and the fan switch.

Torque - Water Temperature Switch: 7.8 N·m (0.80 kgf·m,

69 in·lb)

Radiator Fan Switch: 18 N·m (1.8 kgf·m, 13.0 ft·lb)

Radiator Fan Switch, Water Temperature Switch

Inspection

•

Refer to the Switch and Sensor in the Electrical System
chapter for these inspections.