16-38 ELECTRICAL SYSTEM

Ignition System

•

Set the Hand Tester [A] to the × 25 V DC range, and
connect it to the connector come from harness side as
follows.

Tester (+) terminal [B]

→

BR/W lead

Tester (–) terminal [C]

→

BK/Y lead

Special Tool - Hand Tester: 57001-1394

Needle Adapter Set: 57001-1457

•

Turn the ignition switch on , and read the voltage.

IC Igniter Operation Voltage: Battery Voltage

If the tester reading is not specified one, check the battery
voltage, ignition switch and ignition fuse.

Starter Button Operation Check

•

Remove the seats (see Seat Removal in the Frame chap-
ter).

•

Set the Hand Tester [A] to the × 25 V DC range, connect
it to the IC igniter [B] lead as follows.

Hand Tester (+) Terminal [C]

→

BK/R Lead

Hand Tester (–) Terminal [D]

→

Frame Ground

Special Tool - Hand Tester: 57001-1394

Needle Adapter Set: 57001-1457

•

Turn the ignition switch on and push the starter button.

•

Read the voltage.

Starter Button Voltage: Battery Voltage

If the tester reading is not specified one, replace the IC
igniter.

Ignition Coil Primary Peak Voltage Inspection

•

Remove:

Side Covers (see Side Cover Removal in the Frame
chapter)
Lower Fairings (see Lower Fairing Removal in the Frame
chapter)

•

Remove the spark plug caps from the spark plugs.

•

Attach a good spark plugs to the removed spark plug caps
and ground them to the engine.

NOTE

○

To obtain a correct measurement, the wires as well as
the wire connections must be correct. Take the volt-
age measurement with the proper cylinder compres-
sion (with the spark plugs in the cylinder head). Without
proper compression, a correct measurement cannot be
obtained.