16-60 ELECTRICAL SYSTEM
Switches and Sensors
Radiator Fan Switch Inspection
•
Remove the left lower fairing (see Lower Fairing Removal
in the Frame chapter).
•
Remove the fan switch (see Radiator Fan Switch Re-
moval in the Cooling System chapter).
•
Suspend the switch [A] in a container of coolant so that
the temperature-sensing projection and threaded portion
are submerged.
•
Suspend an accurate thermometer [B] in the coolant so
that the sensitive portions [C] are located in almost the
same depth.
NOTE
○
The switch and thermometer must not touch the con-
tainer sides or bottom.
•
Place the container over a source of heat and gradually
raise the temperature of the water while stirring the water
gently.
•
Using the hand tester, measure the internal resistance
of the switch across the terminals at the temperatures
shown in the table.
If the hand tester does not show the specified values, re-
place the switch.
Radiator Fan Switch Resistance
Rising temperature:
From OFF to ON at 96
∼
100°C (205
∼
212°F)
Falling temperature:
From ON to OFF at 91°C (196°F)
Less than temperature at ON
ON: Less than 0.5
Ω
OFF: More than 1 M
Ω