Руководство пользователя для Kawasaki KLE500 (2004) :: Страница 343 из 401
Service-Instruction.ru
инструкции pdf и руководства пользователя читать онлайн
background image

ELECTRICAL SYSTEM 16-29

Charging System

•

Check that the ignition switch is turned off, and connect
the hand tester [A] as shown in the table.

Special Tool - Hand Tester:57001-1394

•

Start the engine, and note the voltage readings at vari-
ous engine speeds with the headlight turned on and then
turned off. The readings should show nearly battery volt-
age when the engine speed is low, and, as the engine
speed rises, the readings should also rise. But they must
be kept under the specified voltage.

Regulator/Rectifier Output Voltage

Connectings

Tester

Range

Tester (+) to

Tester (–) to

Reading

25 V DC

White

Black/Yellow

Battery Voltage

14

∼

15 V

•

Turn off the ignition switch to stop the engine, and discon-
nect the hand tester.
If the regulator/rectifier output voltage is kept between the
values given in the table, the charging system is consid-
ered to be working normally.
If the output voltage is much higher than the values spec-
ified in the table, the regulator/rectifier is defective or the
regulator/rectifier leads are loose or open.
If the battery voltage does not rise as the engine speed
increases, the regulator/rectifier is defective or the alter-
nator output is insufficient for the loads. Check the al-
ternator and regulator/rectifier to determine which part is
defective.

Regulator/Rectifier Inspection

Rectifier circuit check

•

Remove the left side cover (see Side Cover Removal in
the Frame chapter).

•

Disconnect the regulator/rectifier lead connector [A].

Brown Lead Terminal [A]
White/Red Lead Terminal [B]
Black Lead Terminal [C]
Yellow 1 Lead Terminal [D]
Yellow 2 Lead Terminal [E]
Yellow 3 Lead Terminal [F]

Оглавление инструкции

Инструкции для мототехника Kawasaki

Популярные инструкции Kawasaki