16-30 ELECTRICAL SYSTEM
Charging System
•
Connect the hand tester to the regulator/rectifier as shown
in the table, and measure the resistance of the respective
diodes in both directions, in the sequence in the table.
The measured resistance should be small in one direc-
tion and 10 or more times in the other direction. If the
measured resistance of any of the two wires (White/Red
or Yellow) is small or large in both directions, the rectifier
is damaged; therefore, replace the regulator/rectifier.
Rectifier Circuit Inspection
Connecting terminal
Tester positive
(+) terminal
Tester negative
(–) terminal
Standard
Tester
range
1
Y1
2
Y2
W/R
∞
3
Y3
4
Y1
5
Y2
BK
6
Y3
× 10
Ω
7
Y1
or
8
W/R
Y2
Approximately
1/2 of the entire
graduation
× 100
Ω
9
Y3
10
Y1
11
BK
Y2
∞
12
Y3
NOTE
○
The actual resistance measurement varies with the
tester used and the individual diodes, Generally speak-
ing, it is acceptable if the tester’s indicator swings
approximately halfway.
Regulator Circuit Check
•
Prepare the following:
Test Light Bulb: one 12 V 3.4 W bulb
Batteries: three 12 V batteries
Wires: six wires of appropriate lengths
CAUTION
The test light works as an indicator and also a cur-
rent limiter to protect the regulator/rectifier from ex-
cessive current. Do not use an ammeter instead of
a test light.
•
Check to be sure the rectifier circuit is normal before con-
tinuing.