Руководство пользователя для Kawasaki KLE500 (2004) :: Страница 337 из 401
Service-Instruction.ru
инструкции pdf и руководства пользователя читать онлайн
background image

ELECTRICAL SYSTEM 16-23

Battery

Refreshing Charge

•

Disconnect the battery terminals (see Charging Condition
Inspection).

•

Remove the battery [A].

•

Do refresh-charge by following method according to the
battery terminal voltage.

WARNING

This battery is sealed type. Never remove seal cap
[B] even at charging. Never add water. Charge with
current and time as stated below.

Terminal Voltage: 11.5

∼

less than 12.8 V

Standard Charge

1.2 A × 5

∼

10 h (see following chart)

Quick Charge

5.0 A × 1.0 h

CAUTION

If possible, do not quick charge. If the quick charge
is done due to unavoidable circumstances, do stan-
dard charge later on.

Terminal Voltage: less than 11.5 V

Charging Method 1.2 A × 20 h

NOTE

○

If the current does not flow when charging, raise the
voltage initially (25 V as maximum), and let down the
voltage to charge when the current starts to flow as a
yardstick. If ammeter shows no change in current after
5 minutes, you need a new battery. The current, if it can
flow into the battery, tends to become excessive. Adjust
the voltage as often as possible to keep the current at
standard value (1.2 A).

Battery [A]
Battery Charger [B]
Standard Value [C]
Current starts to flow [D]

•

Determine battery condition after refreshing charge.

○

Determine the condition of the battery 30 minutes after
completion of the charge by measuring the terminal volt-
age according to the table below.

Criteria

Judgement

12.8 V or higher

Good

12.0

∼

less than 12.8 V

Charge insufficient

→

Recharge.

less than 12.0 V

Unserviceable

→

Replace