8-53
Disconnect the main switch coupler from
the wire harness.
Check for continuity as follows:
Red
– Brown / Blue
Disconnect the fan motor coupler.
Connect the battery (12 V) as shown.
2
EB802017
3. Main switch
Replace the main switch.
CONTINUITY
NO CONTINUITY
EB807011
The fan motor is faulty, replace it.
MOVES
DOES NOT MOVE
4. Fan motor
Battery (+) lead
Black terminal
Battery (–) led
Black terminal
Check the operation of the fan motor.
2
1
1
COOLING SYSTEM
ELEC