8-45
SIGNAL SYSTEM
ELEC
1
2
1
1. Bulb and bulb socket
Check the bulb and bulb socket for continu-
ity.
Replace the bulb and / or bulb socket.
CONTINUITY
NO CONTINUITY
3. Diode
Remove the diode from the wire harness.
Check for continuity as follows:
Sky blue
– Light green
Replace the diode.
CORRECT
INCORRECT
2. Neutral switch
Disconnect the neutral switch lead from the
neutral switch.
Check for continuity as follows:
Neutral switch terminal
– Ground
Replace the neutral switch.
CONTINUITY
NO CONTINUITY
Tester (+) lead
Sky blue
Tester (–) lead
Light green
1
Tester (+) lead
Light green
Tester (–) lead
Sky blue
Continuity
No
Continuity
2
1
2
EB806024
4. If the neutral indicator light fails to come on: