8-17
EB803024
5. Starter relay
S
Disconnect the relay unit coupler from the
wire harness.
S
Connect the pocket tester (
Ω
1) and bat-
tery (12 V) to the relay unit coupler termi-
nals.
Replace the starter relay.
NO CONTINUITY
:
CONTINUITY
EB802017
6. Main switch
S
Disconnect the main switch couplers from
the wire harness.
S
Check for continuity as follows:
Red
– Brown / Blue
Replace the main switch.
CONTINUITY
NO CONTINUITY
1
2
:
Battery (+) terminal
Red / White terminal
Battery (–) terminal
Blue / White terminal
3
4
Tester (+) lead
Red terminal
Tester (–) lead
Black terminal
3
4
S
Check the starter relay for continuity.
ELECTRIC STARTING SYSTEM
ELEC