Инструкция для Yamaha FZS600 (1998) :: Страница 101 из 364
Service-Instruction.ru
инструкции pdf и руководства пользователя читать онлайн
background image

3-44

CHECKING AND CHARGING THE BATTERY

CHK

ADJ

NOTE:

CAUTION:

NOTE:

Since MF batteries are sealed, it is not pos-
sible to check the charge state of the battery
by measuring the specific gravity of the elec-
trolyte. Therefore, the charge of the battery
has to be checked by measuring the voltage
at the battery terminals.

1. Remove:

seat

2. Disconnect:

battery leads
(from the battery terminals)

First, disconnect the negative lead 

1

,

then the positive lead 

2

.

3. Remove:

battery

4. Check:

battery charge

a. Connect a digital voltmeter to the battery

terminals.

Tester positive
lead

battery positive
terminal

Tester negative
lead

battery negative
terminal

The charge state of a MF battery can be
checked by measuring its open-circuit volt-
age (i.e., the voltage when the positive ter-
minal is disconnected).

No charging is necessary when the open-
circuit voltage equals or exceeds 12.8 V.

b. Check the charge of the battery, as

shown in the charts and the following ex-
ample.

Example
c. Open-circuit voltage = 12.0 V
d. Charging time = 6.5 hours
e. Charge of the battery = 20 

 30 %

5. Charge:

battery
(refer to the appropriate charging method
illustration)