3-44
CHECKING AND CHARGING THE BATTERY
CHK
ADJ
NOTE:
CAUTION:
NOTE:
Since MF batteries are sealed, it is not pos-
sible to check the charge state of the battery
by measuring the specific gravity of the elec-
trolyte. Therefore, the charge of the battery
has to be checked by measuring the voltage
at the battery terminals.
1. Remove:
seat
2. Disconnect:
battery leads
(from the battery terminals)
First, disconnect the negative lead
1
,
then the positive lead
2
.
3. Remove:
battery
4. Check:
battery charge
a. Connect a digital voltmeter to the battery
terminals.
Tester positive
lead
battery positive
terminal
Tester negative
lead
battery negative
terminal
The charge state of a MF battery can be
checked by measuring its open-circuit volt-
age (i.e., the voltage when the positive ter-
minal is disconnected).
No charging is necessary when the open-
circuit voltage equals or exceeds 12.8 V.
b. Check the charge of the battery, as
shown in the charts and the following ex-
ample.
Example
c. Open-circuit voltage = 12.0 V
d. Charging time = 6.5 hours
e. Charge of the battery = 20
30 %
5. Charge:
battery
(refer to the appropriate charging method
illustration)